Oscillations of anode front-end electronics on the GIF beam at CERN (GIF OFF)  


  • Oscillations.

  • - the most straightforward way to check oscillations presence is to measure a time difference between the first and the second signal in given channel with use of multi hit TDC. The fraction of events with at least two signals in channel is presented for each plane (see page 1 of the Plot , run 365, thresholds from Table 1) . As we see the contribution is less than 1% (channels out of region 9-14 have very small occupancy and therefore large errors). The time difference distribution is on the page 2 of the Plot and the peak is centered at 243 nsec ( corresponding frequency is about 4 MHz). There were a few cases of stable oscillations ("latch" mode) during the run in the GIF hall (see logbook) .


    Last modified: Mon May 31 13:00:00 CST 1999